myplugin.solar walkthrough
Last reviewed: 3 November 2026. This guide walks through the live ENA portal at myplugin.solar, what to have ready before you start, and what to do if the process gets stuck. It is a short job, provided you do not start by hunting for your postcode or email inbox.
~5 min
Typical time
800 VA (3.5 A)
IPS apparent-power and current limits
1
Device per household
No approval
Notification, not consent
What the portal is for
The portal is called UK Plug-in Solar Registration and is operated by Energy Networks Association Limited, company 04832301, at 4 More London Riverside, London SE1 2AU. It notifies your Distribution Network Operator (DNO) after you submit. Check eligibility before using this route. If you already have permanently wired generation, such as rooftop solar or a generating battery inverter, adding the plug-in device must keep the aggregate registered capacity within 16 A per phase. Above that, G99 requires an application. See the Ofgem decision, page 3, in the sources below.
For eligible installations, G98 uses notification. The portal does not approve the installation. Your device still needs to be on the approved list. Electrical safety checks come before connection.
Before you start
SI 2026/848 sets a maximum rated AC output of 800 W. Separately, IPS section 4.1 caps apparent power at 800 VA and maximum current at 3.5 A. These are separate limits. The panel side may total up to 2,000 W DC; above 960 W, the IPS advises considering a professional assessment of the electrical installation. The regulations took effect on 27 August 2026. This network route covers Great Britain; Northern Ireland has separate G98/NI rules.
Check for modern residual-current protection (RCBOs) and an installation in good condition. Older fuse protection without RCBOs needs a professional electrician to check it and upgrade it where necessary (IPS 8.3.2). If the installation's condition is unknown, get a professional assessment before connecting. The IET's 27 August 2026 warning also advises an electrician's assessment before buying or connecting. An RCD alone does not establish suitability.
The IPS warns against connecting or operating the device with a battery energy storage system, including use in conjunction with one. Pairing a solar-only kit with a separate home battery is not covered by this route's warnings and evidence yet. Treat a proposed combination as out of scope unless the device filing and the IPS explicitly cover it. Connect directly to a wall socket. Extension cables and adaptors are not permitted.
Product registration is the manufacturer's job before sale: IPS section 7 requires registration and confirmation of compliance first. Your job is to notify the installation. For an eligible G98 connection, NGED states a deadline of 28 days after connection (commissioning) and calls the process “fit and notify”.
Energy Saving Trust's advice page, checked on 3 November 2026, says to register before use. Its checklist says to register after installation. Those statements differ. The established G98 notification window is within 28 days of connection; it does not impose a blanket ban on use before notification. Register promptly. Safety requirements still apply before you connect.
Have the device to hand, your name, your installation postcode, and an email address you actually check. Allow about five minutes. The email point sounds obvious until the one-time code lands in an inbox you last opened in 2019.
Optional installation record
Our free G98 notification assistant prepares optional supporting paperwork for your own records. Registration happens in myplugin.solar. The assistant does not submit your notification.
The portal steps
The live portal has four steps. Treat them as a registration checklist, not as a buying guide. If a device is not available to select, do not work around it.
1. Verify your email
The portal asks you to continue with a one-time code. Use an address you can access while you are completing the form, because this is not the moment to discover that an old mailbox has locked you out.
2. Confirm your address
Enter your postcode and select the address where the device will be installed. This matters because the portal sends the notification to the relevant DNO. Your energy supplier is not the same thing as the network operator.
3. Select your device
Choose one of the approved devices shown in the portal. A domestic socket device must meet the 800 W rated AC output limit in SI 2026/848. The IPS separately caps apparent power at 800 VA and current at 3.5 A. Select the exact model shown for this route.
If your device is not listed, the portal's own guidance says it may still be undergoing assessment, so checking again in a few days is the first move. Unlisted can mean other things too — the questions section below spells them out. Guessing is a poor compliance strategy.
4. Submit your registration
Review the details and submit. The portal then sends your notification automatically to the DNO. You have registered; you have not applied for approval.
What happens after you submit
The notification goes to the relevant network operator automatically. ENA Connect Direct remains the industry-facing route; myplugin.solar is the consumer route for this plug-in solar registration.
Save the on-screen confirmation immediately, for example as a screenshot. Energy Saving Trust's checklist, checked on 3 November 2026, says you should get this confirmation and will not get an email confirmation. Keep your installation details with it. The G98 notification assistant can make a user-prepared installation record as a PDF. That PDF is not proof of what the portal received. If you replace the device later, use the same process again — and if a device is being permanently removed, tell the network operator so their record matches reality. The portal FAQ says one device per household at any one time.
If you get stuck
Use the portal's Contact Us page for support with the registration itself. The one-time code can land in spam — check there, then resend on the email screen. A postcode that returns the wrong network operator deserves a stop and a re-check on ENA Connect Direct before you submit — the check takes minutes, and the notification still needs to reach the right network within the 28-day deadline. Same rule for the device list: don't pick the nearest lookalike if your exact model is missing — check the register entry printed on the box or the invoice. Save the on-screen confirmation before closing the page. We have not verified a way to recover a lost confirmation through portal support. For general plug-in solar advice, the portal points readers to the Energy Saving Trust website. Do not ask a retailer to turn an unlisted device into an approved one by email. That is not how the list works.
Questions before you register
Is registering through myplugin.solar a legal requirement?
For a connection eligible for G98, notify your electricity network operator within 28 days of commissioning. Check existing generation first: the aggregate limit is 16 A per phase. Above that, G99 requires an application. myplugin.solar is the consumer route that sends that notification for a plug-in solar device, so using it is the straightforward way to comply. Registering on the portal does not approve the installation.
When should I use the portal?
For an eligible G98 connection, notify the network within 28 days of connection (commissioning). NGED describes this as fit and notify. The manufacturer registers the product model before sale; you notify your own installation through myplugin.solar. These are separate jobs. Register promptly, and meet the electrical safety requirements before connecting.
What if my device is not listed?
The portal only lets you select devices that appear on its approved device list. The portal says an unlisted device may still be undergoing assessment, so checking again after a few days is fair. But absence from the list can also mean the model was never submitted, was withdrawn, was found non-compliant on an earlier filing, or falls outside the route (including battery-integrated systems or use with a separate battery) — the register carries non-compliant and withdrawn entries too, not only passes.
Can I register more than one plug-in solar device?
No. The final IPS says “Only one plug-in solar product shall be used per household final ring circuit”, and GB network rules (EREC G98 Issue 2 Amendment 1 2026) currently restrict this to one device per household. The portal FAQ agrees — one device per household at any one time. The network rule can change, so check it before assuming more. Replacement devices go through the same registration process.
Who sees my data?
The portal's own privacy policy says your registration information is shared with the relevant DNO so they can be notified the device will be used at the address, and that it is not shared with other partners or companies. The DNO then becomes the data controller for the device registration, and ENA's processors (Baringa Partners, on AWS Cognito) handle the form itself. Read the current terms at myplugin.solar/privacy.
Does this apply in Northern Ireland?
No. The portal covers the Great Britain plug-in solar route: the network-rule changes made by SI 2026/848 plus G98. Northern Ireland has its own network rules under G98/NI, and the portal is not the route there — check with NIE Networks before installing.
Do I need permission from my landlord or freeholder?
Possibly, yes. GOV.UK tells buyers to check whether permissions are needed before purchasing or installing — that can include landlord or freeholder consent, planning permission, or listed building consent. Getting that in writing first is cheaper than removing a kit later.
Prepare before you submit
Register in myplugin.solar. The G98 notification assistant is optional supporting paperwork. Its PDF does not prove portal submission. Ofgem's DCRP/MP/26/02 decision, page 3, confirms that plug-in installations are exempt from the G98 cut-out photograph requirement. You do not need that photograph for this route.
Sources
- myplugin.solar portal FAQ and privacy policy
- myplugin.solar data privacy policy
- Final plug-in solar Interim Product Specification (DESNZ IPS v2.0 PDF)
- SI 2026/848 on legislation.gov.uk
- National Grid Electricity Distribution G98 page (notify within 28 days of commissioning)
- Retired ENA Type Test Register (closed 16 April 2024; migrated to Connect Direct)
- GOV.UK launch announcement, 26 August 2026 (permissions before purchase)
- Ofgem DCRP/MP/26/02 decision (G98 amendment)
- Energy Saving Trust checklist (on-screen confirmation; no email), checked 3 November 2026
- Energy Saving Trust advice (registration before use), checked 3 November 2026
- IET warning on electrical suitability, 27 August 2026
This page was last reviewed on 3 November 2026. It is guidance, not legal advice.